Amana Furnace Error Codes

Amana HVAC systems are also highly-dependable and efficient. Similar to Trane furnaces, Amana furnaces use a blinking red light to signify an issue with the unit. 

Edmonton homeowners may come across these common Amana furnace error codes.

Amana Furnace Error CodeMeaningPotential Issue
Constant red lightNo signal from thermostatNo power, issue with connections
Constant flashingReversed polarityIssue with wiring or line voltage polarity
1 flashFlame failure / Lockout due to excessive ignition retriesGas supply interruption, flame rod not sensing flame, wiring issue, etc.
2 flashesDraft inducer not operating or pressure switch failure (closed pressure switch circuit)Draft inducer not working, short in the pressure switch, blockage in vent, condensate drain plugged, etc.
3 flashesOpen pressure switchPressure switch needs to be replaced, pressure switch hose improperly connected or blocked, loose wiring, etc.
4 flashesPressure error / High limit errorClogged air filter, drain tubes obstructed by debris or moisture, faulty wiring, etc.
5 flashesFlame sensed without call for heatValve closing too slowly, etc.
7 flashesFaulty flame sensorFlame sensor dirty or too far from flame, etc.